97300 Waste Gas Burner

Shand & Jurs Biogas 97300 Waste Gas Burner PDF
  • High Performance Stoichiometric Pilot

  • No Flame Front Burn-out of Pilot Gas During Ignition

  • Sizes 2" Through 12"

  • Burns High Flow, Low BTU "Wet" Methane

  • No Venturi Maintenance

  • State-of-the-Art Digital Control

    Specification Inquiry


The Shand & Jurs Biogas 97300 Waste Gas Burner is specifically designed for dependable "Flaring" operation that utilizes low BTU anaerobic digester waste gases. The 97300 efficiently incinerates waste gases thus minimizing odors and VOC’s. The stoichiometric pilot ensures that a proper air to fuel mixture is maintained throughout the wide range of pressure and BTU fluctuations experienced in these processes. A continuous or intermittent burning pilot in the flame area provides stable, controlled nonsmoking combustion to minimize odors and VOC emissions. Alarm outputs and automatic controls provide safe, reliable and simple operation.

The 97300 is capable of withstanding a wind speed load of 150 mph and seismic zone 4 loads. Its stainless steel components endure the severest of process environments. The burner tip is designed with swirl inducers that create a cyclonic effect that produces an efficient air/fuel mixture and maximizes flame retention. The wind shroud induces sufficient air to the flare tip for proper mixing and combustion throughout the operating range.

The Pilot Control Panel includes selector switches for the powering, resetting, and emergency stopping of the unit. It also includes indicator lights for power and flame proven.

The flare pilot control system utilizes state of the art electronics and all necessary instrumentation to safely operate the flare system. Pilot controls are enclosed in a NEMA 4, carbon steel, electrical enclosure. The flare pilot, for automatic operation, can be ordered to operate only during initial start up or continuously. The Pilot Control Panel includes a dry contact input for Remote Start. The Pilot Control Panel also includes Contact Status outputs for Alarm and Flame Proven.

The auto-ignition sequence is started by the closing of the remote start contact or pressure switch contact indicating that the gas pressure limit has been reached and flaring of excess gas should begin. Once the sequence begins, the operation of the Burner will continue until the contact opens.

The Shand & Jurs Biogas 97300 is especially designed to combust unwanted biogases generated in fermentation processes like anaerobic digesters, lagoons, and municipal landfills.